Lion Power Modules
Large Standard Footprint up to world class leading 1kW
Output Power
Complete Power System NOT JUST CONVERTER STAGE
Transient Ride-through and input current limit active circuit
Common mode and differential mode magnetic filters with
associate X and Y filter capacitors
Lightning Suppressors
Up to Four Power Converter Channels each with system
characteristics to Resolve Dormancy issues:
• Active Transient Ride-through
• Input current limit
• Automatic Power sharing with defined voltage output characteristics
without Internal Single point of Failure system share line
• Dual Input Capability
Aimed for EMC MIL-STD-461E or DEF-STAN 59-41
TRUE N +1 System Redundancy and Protection on Both Input and
Output Terminals suitable for Battery Charging for Land vehicles
Multi Channel Alarm Bite Monitors:
• Power Good on Output
• Over Voltage Protection
• Re-entrant Multi Alarm Thermal spreading Over Temperature
protection at 105°C and restarts at 95°C, i.e System reduces
power when one channel stops but recommences power
provision as soon as it cools down
Ultimate System
Mechanical Integrity
associated with both
internal and external
connections
Superior Shock
Sustaining and Lowest
weight Category
using State of the Art
Integrated Planar
Magnetics
| |
|
 |
| Lion Series |
|
| |
|
| Specifications |
|
| |
| |
|
|
| Input Characteristics |
|
Protection Characteristics - Multi Channel |
| Module Input Options |
115VAC 400Hz PFC*
270VDC*
28VDC (16V to 42V)
*Dual I/P or 3PH I/P
|
|
Output Over-voltage
Output Over-current
Over-temperature
Reverse Input
Zero Load Operation
Short Circuit
Input Over-current
|
115% of nominal
115~140% of maximum
105°C baseplate
(retries at 95°C)- Each Channel
28VDC Input Only
Yes
Latch or retry option
150% of maximum |
Input Transient (270VDC)
(115VAC 400Hz)
(28VDC)
|
MIL-STD-704E+
MIL-STD-704E+
MIL-STD-704E+ |
Notes:
* Hold up depends on output configuration please see output characteristics.
+ Except Fig. 6, 9, 11 & 12 for undervoltage
|
|
Alarms |
| |
Output Voltage Good, Input Voltage Good and
Over-temperature
VME Bite and Start up signals ACFAIL, SYSRESET and SYSFAIL
Compatible |
| Output Characteristics 1KW peak - Liquid
Cooled or Substantial Heat sink |
|
|
LI001K-DC270D-48/10-48/10-40/A4-40/A4
– Dual 270V DC Input for true N+1
LI001K-DC270S-48/10-48/10-40/A4-40/A4
LI001K-DC270D-24/20A8-24/20A8-40/A4-40/A4
– Dual 270V DC Input for true N+1
LI001K-DC270S-24/20A8-24/20A8-40/A4-40/A4 |
|
Environmental Characteristics |
Temperature
Notes:
Shock
Vibration
Acceleration
Ingress
Mass |
–32°C to +70°C*
*Dependent on cooling method
MIL-STD-810-E
MIL-STD-810-E
MIL-STD-810-E
IP67
<900g |
LI001K-DC270D-28/17A9-28/17A9-40/A4-40/A4
– Dual 270V DC Input for true N+1
LI001K-DC270S-28/17A9-28/17A9-40/A4-40/A4
LI500W-DC270D-5/50-3V3/50-12/2-12N/2-5/A5
– Dual 270V DC Input for true N+1
LI500W-DC270S-5/50-3V3/50-12/2-12N/2-5/A5 |
|
|
|
| |
EMC Characteristics |
| |
270VDC & 115VAC
400Hz Input |
MIL-STD-461E (Aircraft use)
CE102 |
| |
28VDC Input
Note: |
DEF-STAN 59-41 Pt. 6
DCE01
Integrated filtering already exists. Full compliance can be achieved via
known filtering techniques, components and heatsinking enclosure fitted
externally. Please ask factory for details. |
| Load Regulation |
< 1% typical |
| Line Regulation |
< 0.3% typical |
| Ripple and Noise (20MHz BW) |
< 1% typical |
| |
| General Input Options 28VDC 270VDC/ 115VAC |
| Efficiency |
85% |
90% max |
|
|
|
| Isolation |
Input to Case |
500V |
1.4kV |
|
Reliability |
|
| |
Input to Output |
500V |
1.4kV |
|
MTBF |
400khrs as per MIL-STD-217
[F2] (Multiple redundancy) |
| |
Output to Case |
500V |
500V |
|
|
|
| |
|
|
|
|
Optional |
|
| |
|
|
|
|
Intelligent power control digital interface available.
Please ask factory for details. |
| |
|
|
|
| |
| |
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
| |
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
| |
|
Dimensions |
| |
|
|
|
Width: 170mm |
Height: 68mm |
Depth: 45mm |
| Download Data Sheet |
 |
|
|
Please contact us sales@pulse-electronics.co.uk for further information and to detail any particular application.
Our engineering team would be pleased to assist and we welcome the opportunity of working with you. |