| Tiger Series |
|
| |
|
| Specifications |
|
| |
|
| |
|
|
| Input Characteristics |
|
Protection Characteristics - Multi Channel |
| Module Input Options |
115VAC 400Hz PFC*
270VDC*
28VDC (16V to 42V)
*Dual I/P or 3PH I/P
|
|
Output Over-voltage
Output Over-current
Over-temperature
Reverse Input
Zero Load Operation
Short Circuit
Input Over-current
|
115% of nominal
115~140% of maximum
105°C baseplate
(retries at 95°C)
28VDC Input Only
Yes
Latch or retry option
150% of maximum |
Input Transient (270VDC)
(115VAC 400Hz)
(28VDC)
|
MIL-STD-704E
MIL-STD-704E
DEF-STAN 61-5 Pt. 6,
MIL-STD-704E |
Notes: *In order to meet the undervoltage requirements, external holdup
capaitance will be required
Integrated holdup depends on output configuration, please see output
characteristics
|
|
Alarms |
| |
Output Voltage Good, Input Voltage Good and
Over-temperature |
| Output Characteristics – N+1 Redundant |
|
|
Configurable Nominal Outputs
@ Maximum Current for either
270VDC or 115VAC 400Hz
Inputs
Notes: |
48V @ 20.8A
28V @ 35.7A
24V @ 41.7A
15V @ 66.6A
12V @ 75.0A
*Output power is dependent upon battery input - 24V-32V
+When integrated with 12ms internal holdup
Dual O/P versions are available including up to 90V O/P |
|
Environmental Characteristics |
Temperature
Notes:
Shock
Vibration
Acceleration
Drop
Ingress
Mass <
|
–32°C to +70°C*
*Dependent on cooling method
DEF-STAN-0035 Pt. 3 Chp. 2-03 M3
DEF-STAN-0035 Pt. 3 Chp. 2-01 M1
BS 3G100 Pt. 2 Sec. 3 CI 1A & CI12
DEF-STAN-0035 Pt. 3 Chp. 2-04 M4
IP67
4kg (series 1), <7kg (series 2) |
Configurable Nominal
Outputs @ Maximum Current
For 28VDC Input
Notes: |
28V @ 65.0A*
24V @ 60.0A* (30A+)
15V @ 100A* (50A+)
*Output power is dependent upon battery input - 24V-32V
+When integrated with 12ms internal holdup
Dual O/P versions are available including up to 90V O/P
|
|
|
|
| |
EMC Characteristics |
| |
270VDC & 115VAC
400Hz Input |
MIL-STD-461E (Aircraft use)
CE101, CE102, CS101,
CS114, CS116 |
28VDC Input
Note: |
*DEF-STAN 59-41
(Options available for
minimum tested compliance
to Land Class A DCE01,
DCS01, DRE01)
*Form Factor applies to series 2 |
Other Available (Multiple)
Variable Output
Configurations @
Maximum (Single)
Current
for 28VDC Input
Note:
|
5V @ 30.0A+ (60A++)
3V3 @ 20.0A+ (40A++)
±12V @ 2.5A+ (5A++)
5V @ 125A* or
3V3 @ 125A*
+Dual redundant
++Non-redundant
*When integrated with 12ms internal holdup
|
|
|
|
| |
Reliability |
|
| |
MTBF |
> 50,000hrs @ 50°C AUF as
per MIL-HDBK-217[F2] |
Optional |
Intelligent power control digital interface available.
Please ask factory for details. |
| |
|
| Load Regulation |
< 1% typical |
|
| Line Regulation |
< 0.3% typical |
| Ripple and Noise (20MHz BW) |
< 1% typical |
| |
|
| |
|
| General Input Options 28VDC 270VDC/
115VAC |
| Efficiency |
85% |
90% max |
| Isolation |
Input to Case |
500V |
1.4kV |
| |
Input to Output |
500V |
1.4kV |
| |
Output to Case |
500V |
500V |
Dimensions |
| |
|
Series 1: Width: 255mm Height: 46mm Depth: 240mm
Series 2: Width: 255mm Height: 86mm Depth: 240mm |
| Download Data Sheet |
 |
|
|